Sign In | Join Free | My burrillandco.com
burrillandco.com

Zhejiang Jiu Kun Technology Co., Ltd.

Zhejiang Jiu Kun Technology Co., Ltd.

Active Member

4 Years

Home > Electromagnetic Flow Meter >

Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter

Product Categories
Zhejiang Jiu Kun Technology Co., Ltd.
Contact Now
    Buy cheap Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter from wholesalers
     
    Buy cheap Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter from wholesalers
    • Buy cheap Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter from wholesalers
    • Buy cheap Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter from wholesalers
    • Buy cheap Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter from wholesalers

    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter

    Ask Lasest Price
    Brand Name : ZhenHua
    Model Number : EMF8507
    Price : $240.00 - $470.00/Sets
    • Product Details
    • Company Profile

    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter

    Product Paramenters
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Parameter
    Technical Data of Flow Meter Converter
    Display
    3-line English LCD display; directly shows the data of forward and reverse flow, percentage of the flow, and flow velocity.
    Parameter
    Setting
    Set the parameter with the button.
    Language
    Chinese, English
    Current Output
    4-20mA, Load Resistance ≤ 500Ω (can choose with HART protocol )

    PIO
    Choose passive pulse output, active pulse output, state output, or alarm output
    Passive pulse output 30VDC(Off), 200mA(On); 0.0001~5000HZ; pulse width: 50%; duty cycle or the fixed value(≤100ms)
    Active pulse output 0.0001~2HZ,≤150mA,15VDC±20%; pulse width:≤100ms (The default value: 20ms)
    Contact capacity: 30VDC(Off), 200 mA(On)
    Communication
    RS485(MODBUS-RTU, MODBUS-ASCⅡ)
    Power Supply
    220VAC, 24VDC, 100-240VAC
    Alarm
    Empty pipe alarm, reverse alarm, upper limit and lower limit alarm.
    Protection Level
    IP67
    Accuracy
    0.5, 0.3
    Structure
    Integrated type, split type
    Technical Data of Flange Type Sensor
    Application
    All conductive liquids, including water, beverage, various corrosive media, and liquid-solid two-phase fluid (mud, paper pulp).
    Diameter
    DN3~DN2000
    Pressure
    0.6~4.0MPa (Depend on the different diameters, reference sheet 1, special pressure
    can be customized).
    Electrode Material
    SS316L, Hc, Hb, Ti, Ta, W, Pt
    Lining Material
    Ne, PTEE, PU, FEP, PFA
    Temperature
    -40~180 ℃ (Note: limited by the lining material's temperature resistance; for reference, see “Lining Material Selection” sheet).
    Shell Material
    Carbon steel (stainless steel can be customized).
    Protection Level
    IP65, IP67, IP68
    Connection
    GB/T9119-2010 (Can connect with HG20593-2009 flange directly),JIS,ANSI or customized.
    Main Performance of the Electrode Material
    Material
    Code
    Performance of Corrosion Resistance
    316L
    V
    Used in industrial water, domestic water, sewage, neutral solution, and weak acids (carbonic acid, acetic acid, etc).
    Hastelloy Alloy C
    Hc
    Applicable to oxidation resistance acids, such as nitric acid, mixed acid, and chromic acid mixed with sulfuric acid.
    Good corrosion resistance to seawater, alkali solution, and chloride solution.
    Inapplicable to hydrochloric acid and Hydrofluoric acid.
    Hastelloy Alloy C
    Hb
    Good corrosion resistance to non-oxidative acid, alkali, salt.
    Inapplicable to nitric acid.
    Ti
    Ti
    Good corrosion resistance to sea water,chloride,hypochlorite and various hydroxides.
    Inapplicable to reducing acids (hydrochloric acid, sulfuric acid, hydrofluoric acid, etc).
    Ta
    Ta
    Mostly resistant to the corrosion of all chemical media; generally used for hydrochloric acid and sulfuric acid.
    Inapplicable to hydrofluoric acid, alkali, and fuming sulfuric acid.
    Tungsten Carbide
    W
    Good wear resistance; used for the wearing media, such as mud and paper pulp. Poor corrosion resistance.
    Platinum-iridium Alloy
    Pt
    Except for aqua acid and ammonium salt, it is mostly resistant to the corrosion of all of the acidic, alkaline, and salt solutions
    Lining Material Selection
    ♦ For high-temperature media(>=140℃); preference for PFA lining
    ♦ For easy scaling media, such as paper pulp; preference for FEP or PFA lining.
    ♦ For the media with sanitation requirements, select FEP (or PTEE) lining.
    ♦ In case of negative-pressure, select FEP.
    ♦ For the wearing media, such slurry and pulp, select PU or FEP lining.
    Main Performance of the Lining Material
    Material
    Performance of Corrosion Resistance
    Working Temperature
    Applicable Areas
    Diameter (mm)
    PTFE
    Mostly resistant to the corrosion of all chemical media.
    -40~150℃
    All media, except the fluid in negative-pressure pipe and fluids with good wear resistance
    DN15~1200
    NE
    Corrosion resistance to low consistency acid,alkali and salt,besides oil.
    -30~80℃
    Industrial water, sewage, low consistency acid, alkali, and salt solutions.
    DN50~2000
    FVMP
    Corrosion resistance to low consistency acid,alkali and salt.
    Resistant to high temperature and negative pressure.
    -30~150℃
    Industrial water, sewage, hot water, low consistency acid, alkaline and salt solutions.
    DN50~2000
    PU
    Good wear resistance; used for the wearing slurry.
    Poor corrosion resistance.
    -30~80℃
    Liquid containing solid grains (grout,slurry)
    DN15~400
    FEP
    The corrosion resistance is equal to that of PTFE
    -40~150℃
    All fluids, except the wearing media (mortar, etc).
    DN3~400
    PFA
    Corrosion resistance to all chemical media,The temperature resistance is better than FEP.
    -40~180℃
    Same as PTFE; preference for sustained high temperature.
    DN3~400
    Product Application Display
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Product Details
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Hot Products
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Company Profile
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Certificates
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    Logistics
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter
    FAQ
    1Q: How long will you give me the reply?
    A: we will contact you in 1 hours as soon as we can.

    2Q:Could I visit your factory?
    A: Sincerely invite you to visit our factory.
    3Q: Do you provide samples ?
    A: Yes,we have materials in stock to help you to get the samples as soon as we can.

    4Q: How about the quality of the managements ?
    A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.

    5Q: What is your terms of payment ?
    A: We could accept T/T, Paypal, WU ,Credit Assurance.

    6Q: What is the warranty for your product ?
    A: Warranty: 2 years, Lifetime maintenance.
    Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter

































    Quality Hot Selling Alarm Function Electromagnetic Converter Battery Flowmeter Converter Chilled Water Flow Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Jiu Kun Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)